BGPNP - BRAKE CLEANER (AEROSOL) M7-20

  • MSDS: BGPNP
  • Manufacturer: RADIATOR SPECIALTY CO
  • Product Name: BRAKE CLEANER (AEROSOL) M7-20
  • National Stock Number: 6850-01-167-0678
Product Identification

Product ID:BRAKE CLEANER (AEROSOL) M7-20
MSDS Date:04/01/1987
FSC:6850
NIIN:01-167-0678
MSDS Number: BGPNP

Responsible Party
RADIATOR SPECIALTY CO
1400 W INDEPENCE
CHARLOTTE, NC 28234
US

Emergency Phone: 704-377-6555

Info Phone: 704-377-6555

Preparer: I.LIEBMAN/T.DIRECTOR

Cage: 77628

Contractor
RADIATOR SPECIALTY COMPANY
34689 CHARLOTTE, NC 28208 US

Telephone: 704-377-6555/303-623-5716

Cage: 77628

Ingredients

METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 30-70%

OSHA PEL 350 PPM/450 STEL

ACGIH TLV: 350 PPM/450STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PERCHLOROETHYLENE (TETRACHLOROETHYLENE) (SARA III)

CAS: 127-18-4

RTECS: KX3850000

Fraction By Weight: 30-70%

OSHA PEL 100 PPM

ACGIH TLV: 25PPM/100,A3 STEL;94

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 1-3%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES
Health Hazards Acute and Chronic:ACUTE:MAY IRRITATE EYES,SKIN,AND
RESPIRATORY TRACT DEFAT,DIZZINESS,HEADACHE,NARCOSIS.HARMFUL OR
FATAL IF/SWALLOWED CHRONIC:LIVER OR KIDNEY DAMAGE.
Explanation of Carcinogenicity:ANIMAL CARCINOGEN (PERCHLORO-ETHYLENE)
Effects of Overexposure:EYES:IRRITATION;CORNEA DAMAGE.
SKIN:DEFAT,DERMATITIS. INHALATION:DIZZINESS,HEADACHE,NARCOSIS,
INGESTION:HARMFUL OR FATAL IF SWALLOWED,CAN EFFECT LIVER OR
KIDNEYS.
Medical Cond Aggravated by Exposure:PRE-EXISTING CONDITIONS MAY BE
WORSEN.

First Aid

First Aid:EYES:FLUSH WITH WATER FOR AT LEAST 15 MINUTES.CALL A
PHYSICIAN SKIN:WASH WITH SOAP & WATER;REMOVE CONTAMINATED CLOTHES.
INHALATION:REMOVE TO FRESH AIR ;SEEK MEDICAL HELP. INGESTION:DO NOT
INDUCE VOMIT ING;CONSULT A PHYSICIAN AT ONCE.

Fire Fighting

Flash Point:NONE
Extinguishing Media:FOAM,CO*2,DRY CHEMICAL
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA IN AN ENCLOSED
AREA.
Unusual Fire/Explosion Hazard:HCL,TOXIC PHOSGENE FUMES;CONTAINERS MAY
BURST,RUPTURE,OR VENT.

Accidental Release

Spill Release Procedures:USE PROPER PERSONAL PROTECTION;VENTILATE THE
AREA;CONFINE SPILL;WIPE WITH RAGS AND COLLECT FOR PROPER DISPOSAL.

Handling

Handling and Storage Precautions:STORE IN COOL DRY AND WELL VENTILATED
AREA;KEEP AWAY FROM HEAT,ALKALIES,METAL POWDERS.DO NOT PUNCTURE OR
INCINERATE

Exposure Controls

Respiratory Protection:NOT NEEDED IF THERE IS AN ADEQUATE VENTILATION.
Ventilation:LOCAL/GENERAL TO MAINTAIN AN ADEQUATE VENTILATION.
Protective Gloves:BUTYL RUBBER
Eye Protection:CHEMICAL GOGGLES
Other Protective Equipment:IMPERVIOUS CLOTHING(APRON;EYE WASH).
Work Hygienic Practices:AVOID CONTACT WITH SKIN AND EYES.DO NOT BREATHE
VAPORS.DO NOT EAT,DRINK AND SMOKE IN WORK AREA.
Supplemental Safety and Health
MSDS RECEIVED BY DGSC-SLM:MARCH 25,1988.

Chemical Properties

HCC:V2
Boiling Pt:B.P. Text:168F/76C
Spec Gravity:1.41
pH:6-7
Evaporation Rate & Reference:3.0 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS VOLATILE LIQUID WITH CHARACTERISTIC ODOR
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
WATER,ALKALIES,FINELY DIVIDED METALS.
Stability Condition to Avoid:EXTREME HEAT
Hazardous Decomposition Products:HCL, PHOSGENE

Disposal

Waste Disposal Methods:DISPOSE OF COLLECTED MATERIAL IN ACCORDANCE WITH
LOCAL,STATE & FEDERAL REGS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.